Home   |   About Us   |   Category   |   Basket   |   Sales Network   |   Contact Us  
  Home >  Product  >>  Alternator >>   
 
   
  Item# GBWa SERIES  
 

 

  

 

  TECHNICAL DATA

 

                                                                                     Type Item

                        GBWa-L1

GBWa-L2

Generating

Working State

(AC)

Frequency (HZ)

50

60

50

60

Rated power (KW)

2.8

3.3

3

3.5

Rated voltage (AC) (V)

230

120/240

230

120/240

Rated current (AC) (A)

12.2

27.5/13.7

13

29/14.5

Power factor (cos ¡é)

1

Welding

Working State (DC)

No-load welding voltage (DC) (V)

65

Rated welding current (DC) (A)

160

180

Welding operating voltage (DC) (V)

25-32

Welding load persistence rate

40%

Welding current adjustment scope (A)

50-180

60-200

Rated speed (r/min)

3000

3600

3000

3600

Electrical Performance

Insulation class F

CONT. S1

Steady-state voltage regulate rate (cos¡é=1)  4%

Generator unload voltage wave rate when welding-current is maximum 2.7%

Generator load voltage wave rate when welder is working 2.2%

Power of generator when welder is working

1.5kw-1.8kw

  Hits£º2091  Write Time£º2008-10-23 ¡¾Print The Page¡¿¡¾Return¡¿
   
   

 

 
Home   |   About Us   |   Category   |   Basket   |   Sales Network   |   Contact Us  
     
ADDRESS£ºC SUITE 19/F,BIAO LI BUILDING,NO.99 HU DONG RD.,FUZHOU CHINA    WEBSITE£ºwww.sinopower-02.com
TEL£º0086-591-87509983¡¢87614242    FAX£º0086-591-87510710    E-MAIL£ºsales1@sinopower-02.com  ICPÖ¤£ºÃöICP±¸18019000ºÅ-2